Directly addressing long throw distances, dynamic passenger heat loads, and perimeter climate isolation in modern architectural aviation spaces.
High-velocity kinetic air sealing for automatic terminal sliding doors and passenger boarding bridge (PBB) thresholds, preventing apron exhaust infiltration.
Learn More
Equipped with integrated spherical jet nozzles capable of delivering air up to 35 meters across clear-span terminal check-in halls without overhead sheet metal ducts.
Learn More
Ultra-quiet, architectural ceiling cassette outlet delivering uniform 360-degree radial laminar distribution for VIP airport lounges and customs counters.
Learn More
Compact, high-capacity ceiling air conditioning units optimized for transitional gate corridors, baggage reclaim transfer zones, and mezzanine hubs.
Learn More
Commercial airport terminals represent one of the most demanding frontiers for building services engineering. Contemporary hub airports—featuring continuous clear spans exceeding 100 meters, soaring ceiling heights of 15 to 25 meters, and monumental glazed envelope facades—demand a fundamental paradigm shift away from legacy ducted HVAC layouts. Traditional centralized ducted systems encounter insurmountable technical hurdles: excessive structural dead loads on slender roof trusses, aerodynamic pressure loss along sprawling transit corridors, aesthetic disruption of organic undulating ceilings, and high lifecycle maintenance over unreachable ceiling voids.
The contemporary standard for airport terminal climate control is anchored by ductless large-span ventilation coupled with decentralized high-induction jet air delivery. By positioning intelligent jet terminal conditioning units, spherical high-velocity discharge nozzles, and aerodynamic vortex diffusers around the structural perimeter and structural column nodes, mechanical systems deliver target air volumes directly into the occupied zone (0 to 2.5 meters above floor level) without requiring millions of square feet of overhead galvanised steel ducting.
Modern mega-hubs operate under extreme operational volatility. Thermal loads are neither steady nor evenly distributed:
The core technological engine driving ductless airport ventilation is the KDS(X) Jet Air Conditioning Unit combined with adjustable Spherical Long-Distance Nozzles. Unlike conventional low-velocity louver grilles that rely on localized displacement or dump distribution, spherical jet nozzles accelerate supply air to controlled exit velocities between 6 m/s and 14 m/s. This high kinetic velocity induces an aerodynamic entrainment ratio of up to 1:15, meaning every cubic meter of conditioned primary air pulls fifteen cubic meters of ambient hall air into its secondary circulation loop.
During cold-climate heating cycles, hot air naturally ascends toward the terminal's vaulted roof due to Archimedes buoyancy forces. Without ductless jet units directing momentum downwards, temperatures at roof level can exceed 32°C while the floor-level passenger zone shivers at 16°C. Variable-angle motorized nozzles automatically tilt downward (between 15° and 35°), driving heated air down to counter natural convection. This minimizes transmission heat loss through roof purlins and preserves passenger thermal comfort in accordance with ASHRAE 55 standards.
Conversely, in cooling cycles, the target is occupied zone displacement. Cool air is delivered horizontally at elevations between 3.5m and 5.0m, forming a chilled microclimate reservoir over passengers while allowing convective solar heat absorbed by skylights to hover harmlessly in the upper unoccupied ceiling envelope. This selective stratification technique reduces chiller refrigeration capacity by 22% to 35% compared to total-volume ducted mixing systems.
Maintaining a constant, comfortable temperature for twenty years, creating a new future with precision air management in mission-critical aviation spaces.
Precise temperature control and comfortable air, serving as the core partner of the central air conditioning system in all scenarios, from customs booths to administrative control rooms.
Learn More
Invisible air barrier, empowering comfort and energy efficiency across wide automated entrance vestibules, boarding gates, and curbside luggage handling bays.
Learn More
Embedded central air conditioning providing beauty and comfort in one step, flush-mounted within false ceilings of VIP terminal suites and executive meeting salons.
Learn More
Directional flow control, intelligent air supply, unlocking a high-induction solution for comfortable airflow traversing immense departure halls without drag.
Learn More
High-end air conditioning terminal equipment integrating high-pressure fan, coil, and jet nozzle to deliver long-distance, large-span coverage without complex ductwork.
Learn More
Advanced vortex ventilation technology creating high-induction mixing, minimizing vertical temperature gradients in transfer transit hubs and central retail atriums.
Learn More
Multi-stage environmental protection equipment combining mechanical interception, high-voltage electrostatic adsorption, and plasma ionization for airport concession restaurants.
Learn More
Heavy-duty smoke exhaust, ventilation, and air exchange machinery engineered for tunnel corridors, luggage sortation facilities, and terminal life-safety pressurization.
Learn More
The airport terminal of tomorrow combines ductless mechanical engineering with real-time artificial intelligence. Through deep integration with modern Building Management Systems (BMS) and flight information display systems (FIDS), terminal HVAC networks no longer react passively to thermal changes; they anticipate them.
By interfacing directly with arrival and departure flight schedules, the ductless jet air conditioning system automatically pre-cools or pre-ventilates specific gate holds 25 minutes prior to the boarding process or deplaning wave. Once passengers board, airflow output throttles down into energy-conservation sleep modes. This dynamic demand-controlled ventilation (DCV) strategy reduces annual terminal fan power consumption by over 30% compared to continuous constant-volume operation.
Airport terminals face unique outdoor contaminants: unburnt hydrocarbons (UHC), polycyclic aromatic hydrocarbons (PAH), and volatile organic compounds (VOCs) originating from aircraft taxiing and auxiliary power unit (APU) burns. By pairing Activated Carbon Adsorption Boxes with high-efficiency synthetic media and plasma purification stages, makeup air entering the ductless jet system is thoroughly scrubbed, maintaining compliance with the most stringent indoor air quality (IAQ) criteria defined in LEED v4.1 Operations and Maintenance.
Standing on the mountain peak, we can see the farther world. Discover why premier civil aviation projects partner with Yuanxin HVAC.
Having deep cultivation in the central air conditioning field for twenty years, we have always been committed to the mission of "creating a comfortable, healthy and energy-efficient indoor environment for humanity".
Not only do we produce air conditioners, but we also strive to provide customers with comprehensive air quality management solutions through innovative aerodynamic and thermodynamic technologies.
In the future, we will continue to promote the green transformation of the industry with intelligent and sustainable products and services, making every aviation space breathe cleanly.
We have obtained 28 international certifications such as ISO9001, ISO14001, OHSAS18001, American AHRI, and EU CE, ensuring complete global airport engineering compliance.
Explore the full range of original components engineered for high-induction jet air delivery, particulate extraction, and thermal isolation.
Equipped with electrostatic high-efficiency filtration cells, designed for concealed mounting above security and staff service zones.
Configuration Details
Features adjustable radial guide vanes producing a high-induction rotational swirl throw, rapidly lowering localized temperature deltas.
View Technical Specs
Manual or actuator-driven pivoting ball nozzle offering 360-degree rotation and up to 30-degree directional tilt for long spans.
Explore Characteristics
Engineered for large-volume air circulation, pressurization, and emergency high-temperature smoke exhaust in concourses.
Performance Curves
Specialized filter chamber neutralizing jet fuel kerosene vapors, apron exhaust gases, and volatile chemicals in terminal fresh air intakes.
Filtration Ratings
High-voltage electrostatic precipitation with up to 98% oil mist removal efficiency for terminal food halls and concession galleys.
Purification System
Nozzle-directed impulse fans for sub-terminal car parks, underground transfer tunnels, and expansive baggage staging zones.
Air Jet Guidance
Acoustically insulated cabinet centrifugal fan box engineered for high static pressures and continuous 24/7 reliability in technical rooms.
Technical Specs
Ductless jet conditioning systems rely on the physics of free turbulent jet entrainment. By propelling primary conditioned air at high velocities (up to 12-14 m/s) through spherical nozzles or high-induction discharge geometries, the jet entrains vast volumes of secondary room air along its trajectory. This continuous aerodynamic momentum transfers thermal energy rapidly, thoroughly mixing air masses across spans of 30 to 45 meters before the stream decelerates to a gentle 0.25 m/s in the human comfort envelope.
Glass facades in airport concourses represent significant perimeter cooling loads in summer and radiant heat sinks in winter. By establishing dedicated high-induction linear slot diffusers or perimeter jet units tilted towards the glass surface, the system creates a micro-climate buffer zone. This air curtain prevents hot convective plumes or descending cold air drafts from penetrating deep into passenger seating rows.
Independent airport engineering assessments demonstrate three major capital and operational savings:
Our airport-grade ventilation solutions are certified under AHRI, CE, and ISO frameworks. By integrating EC electronically commutated variable-speed motor drives, high-efficiency copper tube hydrophilic aluminum fin heat exchangers, and localized demand-controlled ventilation (DCV) sensor loops, our systems contribute directly toward LEED Energy and Atmosphere (EA) points as well as Indoor Environmental Quality (EQ) credits for enhanced acoustic performance and thermal comfort satisfaction.