The KD(X) series ceiling air conditioning units are premium end-mounted air handling units tailored for central air conditioning systems. Designed to filter, cool, dehumidify, heat, add humidity, and introduce fresh air, these units are ideal for delivering conditioned air through ductwork over longer distances. They are particularly effective for small commercial and industrial building air conditioning projects. This versatile series includes 13 models and 39 specifications, with air volume capacities ranging from 1500m³/h to 15000m³/h and cooling capacities from 8.4kW to 324.8kW. Available in attractive white or blue finishes, each unit is equipped with durable nylon filters. The heat exchanger is constructed with high-efficiency copper tubes and aluminum fins, enhancing the heat exchange efficiency after mechanical expansion.

,

Characteristics of Modern Production:

,

● Superior Quality

,

● Cost-Effective Solutions

,

● Rapid Production Cycle

,

As a trusted China supplier and factory of advanced air conditioning solutions, we prioritize quality and performance in every product we deliver.

,

    Installation of the unit

    • The air conditioning unit should be installed horizontally within the ceiling cavity. The side of the condensate water pipe is allowed to be slightly lower by 0.5% but not higher, to ensure the smooth discharge of the condensate water. There should be sufficient installation and maintenance space around the unit.
    • The condensate water discharge connected to the unit must have a water seal, and the water seal should have sufficient height.
    • The connecting pipe of the evaporator is inlet-down and outlet-up. A stop valve and filter should be installed at the inlet.
    • The air duct connected to the unit needs to be flexibly connected. The water pipe connected to the unit should use a flexible connection. The torque during connection should not be too large to avoid damaging the heat exchanger. The pipeline must have a separate support and the weight should not be borne by the unit.
    • The motor of the fan should have good grounding. In addition, it should have other reliable protection devices such as overload, overheating, and phase loss.
    Installation of the unit

    Operation and Maintenance of the Unit

    • The cold and hot media of the unit should be clean softened water, and the working pressure should not exceed 1.6 Mpa.
    • During normal operation of the unit, the temperature rise of the fan bearings should not exceed 40℃.
    • The outlet pipe of the unit is equipped with an exhaust valve. Before the first operation and during the cold and hot conversion, the exhaust valve should be opened to discharge the air in the heat exchanger and pipeline to avoid affecting the heat exchange effect. The summer cooling water temperature of the unit should not be lower than 5℃, and the winter hot water temperature should not be higher than 70℃.
    • In extremely cold regions in winter and when the fresh air unit is in heating mode, the heating unit should be turned on for 5-10 minutes first, then the supply fan should be started to prevent the formation of ice plugs in the heat exchanger due to the accumulation of cold air; when shutting down, the fresh air valve should be closed first, then the heating unit, and finally the supply fan.
    • When the unit is not in use in winter, the water in the coil should be drained, and the pipe should be dried with compressed air. If the water cannot be blown clean, antifreeze should be added to the pipe. If the unit is not in operation for a short time in winter, ensure that there is hot water circulation in the pipe to prevent rust and freezing. Except for winter, when the heat exchanger is not in use in other seasons, it should also be filled with water to reduce corrosion.
    • Filters should be cleaned regularly to ensure the performance of the unit. If the air volume decreases, it is generally caused by excessive dust accumulation in the filter.
    • After one month of operation of the unit, check whether the fastening bolts and the solid bolts of the fan are loose.
    • After two to three years of operation of the unit, a comprehensive maintenance should be carried out, remove the scale in the heat exchanger tube, clean the heat exchanger fin with compressed air or water. The lubrication parts of the fan, motor, etc. should be regularly lubricated with oil.

    Frequently Asked Questions (FAQ)

    How should the air conditioning unit be installed to ensure proper drainage?

    The unit should be installed horizontally within the ceiling cavity. The side of the condensate water pipe can be slightly lower by 0.5% but not higher, ensuring the smooth discharge of condensate water.

    What are the water temperature limits for summer cooling and winter heating?

    The summer cooling water temperature of the unit should not be lower than 5℃, and the winter hot water temperature should not be higher than 70℃.

    How can you prevent ice plugs in the heat exchanger during extremely cold winters?

    Turn on the heating unit for 5-10 minutes first before starting the supply fan. When shutting down, close the fresh air valve first, followed by the heating unit, and finally the supply fan.

    What maintenance should be performed on the unit during winter when not in use?

    Drain the water in the coil and dry the pipe with compressed air. If water cannot be blown clean, add antifreeze. For short-term shutdowns, ensure there is hot water circulation to prevent rust and freezing.

    What is the recommended frequency for comprehensive maintenance and scale removal?

    A comprehensive maintenance should be carried out after two to three years of operation. This includes removing scale in the heat exchanger tube, cleaning the fins with compressed air or water, and regularly lubricating the fan and motor parts.

    Make an free consultant

    Your Name*

    *Name Cannot be empty!

    Phone Number

    Country

    Remarks*

    * Enter product details such as size, color,materials etc. and other specific requirements to receive an accurate quote. Cannot be empty
    *Need to accept terms
    reset