Product Feature
1. Cabinet: The cabinet is composed of a high-sealing profile frame and low-thermal-resistance wall panels made of color steel plates. The frame is an aluminum alloy profile skeleton; the wall panels are polyurethane integral foaming with a thermal conductivity of less than 0.022 w/m.℃. High-density polystyrene wall panels or glass wool wall panels can also be used.
2. Fan: A low-noise and high-efficiency external rotor or belt-driven centrifugal fan is adopted. The fan has undergone precise dynamic balance correction to ensure smooth operation of the unit, featuring low noise and high total pressure.
3. Heat Exchanger: The main body of the heat exchanger is made of high-quality seamless copper tubes and high-purity aluminum foil, which are mechanically expanded and then tested for hydraulic sealing at 2.4 MPa. The performance meets the requirements of the GB/T14294-2008 standard, ensuring the superior performance and reliable quality of the product.
2. Fan: A low-noise and high-efficiency external rotor or belt-driven centrifugal fan is adopted. The fan has undergone precise dynamic balance correction to ensure smooth operation of the unit, featuring low noise and high total pressure.
3. Heat Exchanger: The main body of the heat exchanger is made of high-quality seamless copper tubes and high-purity aluminum foil, which are mechanically expanded and then tested for hydraulic sealing at 2.4 MPa. The performance meets the requirements of the GB/T14294-2008 standard, ensuring the superior performance and reliable quality of the product.
4. Dry Condensate Pan: The carefully designed condensate pan and thick inner insulation material ensure that there is no condensation in the unit under harsh environmental conditions. The condensate pan is designed with an inclined structure, which is more conducive to the drainage of condensate water. At the same time, the condensate pipe is calculated under non-full conditions, and the drainage capacity is more than five times the normal operating drainage volume of the unit. The timely drainage of condensate water reduces the "contact water" time of the condensate pan, which not only helps to reduce the corrosion of the condensate pan but also avoids the growth of bacteria in the condensate pan.
5. Air Outlet: A spherical nozzle with excellent jet performance is used as the air outlet, which can achieve long-distance air supply without ducts. The spherical air outlet can be selected for horizontal or vertical air supply. It is particularly suitable for large spaces, especially for the warm air supply in large workshops. When air is supplied horizontally, the air supply angle can be manually or automatically adjusted up and down within a 60° range using a controller, allowing cold and hot air to reach the desired position. When air is supplied vertically, an automatic swing controller can be configured according to user requirements. In winter, the spherical nozzle is fixed and supplies air vertically over a long distance, allowing the hot air to reach the desired position. In summer, the spherical nozzle can swing automatically left and right within a 60° range, simulating natural wind, avoiding the discomfort caused by cold air, and solving the contradiction of difficult coordination between hot air in winter and cold air in summer.
6. Air Filter: A specially designed plate-type air filter can be conveniently pulled out from the left, right, top, or bottom of the unit, making it particularly suitable for maintenance and cleaning in compact spaces. The filter material can be made of nylon mesh or non-woven fabric.
7. Control: An intelligent speed control system designed and manufactured by our company can be optionally equipped. It automatically adjusts the air supply volume of the air conditioning unit according to the air conditioning load, and can operate with fresh air during the non-air conditioning season.
5. Air Outlet: A spherical nozzle with excellent jet performance is used as the air outlet, which can achieve long-distance air supply without ducts. The spherical air outlet can be selected for horizontal or vertical air supply. It is particularly suitable for large spaces, especially for the warm air supply in large workshops. When air is supplied horizontally, the air supply angle can be manually or automatically adjusted up and down within a 60° range using a controller, allowing cold and hot air to reach the desired position. When air is supplied vertically, an automatic swing controller can be configured according to user requirements. In winter, the spherical nozzle is fixed and supplies air vertically over a long distance, allowing the hot air to reach the desired position. In summer, the spherical nozzle can swing automatically left and right within a 60° range, simulating natural wind, avoiding the discomfort caused by cold air, and solving the contradiction of difficult coordination between hot air in winter and cold air in summer.
6. Air Filter: A specially designed plate-type air filter can be conveniently pulled out from the left, right, top, or bottom of the unit, making it particularly suitable for maintenance and cleaning in compact spaces. The filter material can be made of nylon mesh or non-woven fabric.
7. Control: An intelligent speed control system designed and manufactured by our company can be optionally equipped. It automatically adjusts the air supply volume of the air conditioning unit according to the air conditioning load, and can operate with fresh air during the non-air conditioning season.